#304600 - 01/12/2007 11:51
Re: Electrical question
[Re: Redrum]
|
carpal tunnel
Registered: 29/08/2000
Posts: 14506
Loc: Canada
|
Quote:
Quote:
Quote:
Guesses for breakers: Furnace – 30 amp Dishwasher – 20 amp Range - 50 amp Total house outlet breakers – 40 amp Dryer – 30 amps
The Dishwasher would only count as 10 amps in that simple calculation, because it's a 120V circuit. (Things are actually slightly more complex than that, but not enough to matter for this purpose).
Yea, I thought I was a little high on the dishwasher I figured maybe some of the units that heat water quickly may draw a bit more
Yes, your 20A number was totally correct (code, actually), but it's 20A at 120V, whereas all of the other numbers given there were for 240V circuits. So the DW really only counts for 10A when considered for the 240V sums. That's all.